    Brand Name : 3nh
    Model Number : YS6010
    Certification : CE, TUV, FCC, ISO9001, RoHS
    Price : Please send inquiry
    Payment Terms : T/T
    Supply Ability : 1000 Unit per Month
    Delivery Time : 5-8 Days
    • Product Details
    • Company Profile

    Reflectance / Transmission 3nh Spectrophotometer YS6010 For Color Measurement

    Reflectance and transmission spectrophotometer for color measurement YS6010


    ModelBenchtop Spectrophotometer YS6060Benchtop Spectrophotometer YS6010
    Optical Geometry

    Reflective : d/8°(diffused illumination, 8-degree viewing angle);SCI&SCE / SPIN&SPEX;Including / excluding UV measurements

    Transmissive : d/0°(diffused illumination, 0-degree viewing angle);SCI&SCE / SPIN&SPEX;Including / excluding UV measurements

    Comply to standard CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7

    ApplicationIt is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.
    Integrating Sphere SizeΦ154mm
    Light Source360~780nm Combined LED Lamp, 400nm Cut-off light source,420nmCut-off light source360~780nm Combined LED Lamp, 400nm Cut-off light source
    Wavelength Range360~780nm
    Spectral Separation DeviceConcave grating
    Detector256 Image Element Double Array CMOS Image Sensor
    Wavelength Range360~780nm
    Wavelength Pitch10nm
    Half Bandwidth10nm
    Reflectance Range0~200%
    Measuring Aperture

    Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;

    Transmissive : Φ30mm/Φ25mm;


    Reflective : Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;

    Transmissive : Φ30mm/Φ25mm;


    Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
    Specular ComponentReflectance: SCI&SCE Transmittance: SCI&SCE
    Color SpaceCIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
    Color Difference FormulaΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter)
    Other Colorimetric Index

    WI (ASTM E313, CIE/ISO, AATCC, Hunter),
    YI (ASTM D1925, ASTM 313),
    TI (ASTM E313, CIE/ISO),
    MI (Metamerism Index),
    Staining Fastness, Color Fastness, Color Strength,

    Opacity,8° Glossiness, Gardner Index, Pt-Co Index, 555 Index,

    Observer Angle2°/10°
    IlluminantD65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
    Displayed DataSpectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset
    Measuring TimeAbout 3s (Measure both SCI & SCE about 6s)
    Repeatability

    Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%)

    Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)

    Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

    Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)

    Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)

    Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

    Inter-instrument ErrorΦ25.4mm/SCI, Within ΔE*ab 0.15(Average for 12 BCRA Series II color tiles)
    Size370×300×200mm(L*W*H)
    Weight9.6kg
    PowerAC 24V, 2A Power adapter power supply
    Illuminant Life Span5 years, more than 3 million times measurements
    Display7-inch TFT color LCD, Capacitive Touch Screen
    Data PortUSB & Bluetooth, Print serial portUSB, Print serial port
    Data Storage Capacity

    Standard: 5000 Pcs; Sample: 40000 Pcs.

    (One PCS can include both SCI and SCE)

    Standard: 2000 Pcs; Sample: 20000 Pcs.

    (One PCS can include both SCI and SCE)

    LanguageEnglish & Chinese
    Working EnvironmentTemperature: 0~40℃; Humidity: 0~85% (No Condensation)
    Storage EnvironmentTemperature: -20~50℃; Humidity: 0~85% (No Condensation)
    Standard AccessoryWhite and Black Calibration Board, Checking Green Board, Sample Holder, Φ4mm, Φ8mm, Φ15mm, Φ25.4mm Aperture, Power Adapter, USB Cable, User Guide, PC Software, Transmissive Test ComponentWhite and Black Calibration Board, Checking Green Board, Sample Holder, Φ4mm, Φ8mm, Φ25.4mm Aperture, Power Adapter, USB Cable, User Guide, PC Software
    Optional AccessoryMicro-printer,Micro-printer, Transmissive Test Component
    Notes: The specifications are subject to change without notice.

    YS6010 spectrophotometer is a bench-top measurement instrument designed to evaluate the color and appearance of many measuring applications for objects’ reflectance and also the transmittance of translucent or transparent liquids and solids. It is a compact yet advanced instrument that features a side port in horizontal format and with 7.7 inch TFT touch screen, it’s very easy to operate.


    With high precision and advanced capabilities, YS6010 benchtop spectrophotometer is designed for accurate analysis and transmission of laboratory color and appearance of solids, liquids, pastes, powders, pills, and granules in a more comprehensive, streamlined process. Model YS6010 is good used in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.


    Application Industry

    Grating spectrophotometer can easily achieve color transferring , and be used as a precision instrument for color matching system. It's widely used in plastics, electronics, painting, ink, textile and garment, printing and dyeing, printing paper, automotive, medical, cosmetics and food industries, scientific research institutes, schools and laboratories.


    Packing & Delivery:


    Size45*50*32mm
    Gross weight15kg
    Standard accessoryPower Adapter, User Guide, CD Disk(PC Software), USB cable, White and Black Calibration Cavity, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber.
    Optional accessoryUniversal test components, micro printer, power test box

    Reflectance and transmission spectrophotometer for color measurement YS6010

    Quality Reflectance / Transmission 3nh Spectrophotometer YS6010 For Color Measurement for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen ThreeNH Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)