Sign In | Join Free | My himfr.com
Home > Haze Meter >

3nh YH1000 Haze Meausring Instrument ASTM D1003 Non Compensation Method

    Buy cheap 3nh YH1000 Haze Meausring Instrument ASTM D1003 Non Compensation Method from wholesalers
     
    Buy cheap 3nh YH1000 Haze Meausring Instrument ASTM D1003 Non Compensation Method from wholesalers
    • Buy cheap 3nh YH1000 Haze Meausring Instrument ASTM D1003 Non Compensation Method from wholesalers
    • Buy cheap 3nh YH1000 Haze Meausring Instrument ASTM D1003 Non Compensation Method from wholesalers

    3nh YH1000 Haze Meausring Instrument ASTM D1003 Non Compensation Method

    Ask Lasest Price
    Brand Name : 3nh
    Model Number : YH1000
    Certification : CE, TUV, FCC, RoHS, ISO9001
    Price : Please send inquiry
    Payment Terms : T/T
    Supply Ability : 500 Units per Month
    Delivery Time : 2-5 Days
    • Product Details
    • Company Profile

    3nh YH1000 Haze Meausring Instrument ASTM D1003 Non Compensation Method

    YH1000 haze meter with ASTM D1003 non-compensation method


    YH1000 haze meter can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test. Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1000 haze meter uses a PDF array detector to meet the CIE V(λ)2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability.


    Technical Advantage

    1. Double standard ISO & ASTM

    Able to meet the test standard requirements of different users, in accordance with ASTM D1003/1044,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136

    2. Easy to operate, faster and more accurate measurement

    The YH1000 haze meter is equipped with a large-size touch screen for easy operation.With a PD array detector, CIE V(λ)2 degree visual response enables high precision and repeatable transmittance and haze measurements.USB data output device for docking with laboratory system.

    3. Dynamic measurement

    Independent light source detector and temperature sensor, constantly monitor light source and environmental change, ensure the reliability of test data.

    4. Easy to measure and widely applicable to samples

    Open measuring area, vertical and horizontal testing, suitable for more samples to be tested.

    5. Quality control software

    It provides powerful software for measuring and analyzing haze and light transmittance, which is suitable for quality monitoring and tabulated management of haze and light transmittance data in various industries.The management of users will be digitized at the PC end, the difference of haze and light transmittance will be compared, and the test report form will be generated to facilitate customer customization and management.

    Application

    YH1000 haze meter is widely used in glass processing, plastic processing, film processing, screen processing, packaging industry, liquid pharmaceutical analysis and other aspects.

    Specification

    Product modelYH1600 Haze MeterYH1200 Haze MeterYH1100 Haze MeterYH1000 Haze Meter
    GeometryTransmittance: 0/D (parallel illumination, diffuse receiving);Conform to the standards: ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, GB/T 3978, ASTM E308, JIS K7105, JIS K7361, JIS K 7136Transmittance:0/D (Parallel light illumination, diffuse viewing); Conform to the standards:ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136Transmittance:0/D(Parallel light illumination, diffuse viewing);Conform to the standards:ASTM D1003/1044, ISO 14782,GB/T 2410, JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136Transmittance:0/D(Parallel light illumination, diffuse viewing);Conform to the standards:ASTM D1003/1044,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136
    CharacteristicThe instrument can easily realize ASTM D1003 non-compensated method, ISO 13468 compensation method, full transmittance, haze test. The instrument can accurately collect the transmittance curve of the transmitted sample, and can accurately output various chroma data of the transmitted sample. High hardware configuration, open measurement area, vertical, horizontal testing. It is widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis and other aspects.The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance,haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection.The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection.The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection.
    Integrating sphere sizeΦ 154 mmΦ154mmΦ154mmΦ154mm
    Light source400 ~ 700 nm combined LED light source (wavelength scalable customized)400nm to 700nm, combined LED light400nm to 700nm, combined LED light400nm to 700nm, combined LED light
    Spectrophotometric ModeConcave grating///
    Sensor256 pixel dual array CMOS image sensorThe PD array detector satisfies CIE V(λ)2 degree visual responseThe PD array detector, satisfies CIE V(λ)2 degree visual responseThe PD array detector, satisfies CIE V(λ)2 degree visual response
    Wavelength range400 ~ 700 nm (wavelength scalable customization)///
    Wavelength interval10 nm///
    Half bandwidth10 nm///
    Measurement Range0-100%0~100%0~100%0~100%
    Measuring apertureΦ20 mm/Φ15 mm/Φ8 mm/Φ4 mm (select single aperture)Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture)Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture)Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture)
    Sample sizeThickness less than 170 mmThickness <170mmThickness <170mmThickness<170mm
    Color spaceCIE LAB, XYZ, Yxy, LCh, s-RGB, βxy///
    Chromatic formulaΔEab, ΔE94, ΔEcmc (2:1), ΔEcmc (1:1), ΔE00///
    Other chromaticity indexHaze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM), WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), Absorbance, Cobalt Platinum Index, Gardner IndexHaze(ASTM D1003/1044,ISO13468),Transmittance T(ISO),Transmittance T(ASTM)Haze(ASTM D1003/1044),Transmittance T(ASTM)Haze(ASTM D1003/1044),Transmittance T(ASTM)
    Observer angle2 °/10 °
    Light sourceD65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30D65,A,CD65,A,CD65,A,C
    Display DataSpectrogram, sample chroma value, color difference/graph, color graph, color simulation, pass/fail resultPASS/FAIL ResultPASS/FAIL ResultPASS/FAIL Result
    Measurement timeAbout 1.5sAbout1.5sAbout1.5sAbout1.5s
    Resolution0.01 unit0.01unit0.01unit0.01unit
    RepeatabilityΦ20 mm aperture, less than 0.08 (after instrument preheating and correction, test the standard nebulizer with the nebulization of about 40 at an interval of 5s for 30 times of standard deviation)Φ20mm,within 0.1 (After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 40 for 30 times were taken at intervals of 5s.)Φ20mm,within 0.1(After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 40 for 30 times were taken at intervals of 5s.)Φ20mm,within 0.15 (After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 40 for 30 times were taken at intervals of 5s.)
    Inter-instrument ErrorΦ20 mm aperture, less than 0.4 (after instrument preheating and correction, test the standard deviation between the standard nebulizer of nebulization and the reference value at an interval of 5s)Φ20mm,with 0.4 (After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.)Φ20mm,with 0.4(After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.)Φ20mm,with 0.4 (After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.)
    DimensionsLength * Width * Height = 290*211*511 mmL*W*H=290X211X511mmL*W*H=290X211X511mmL*W*H=290X211X511mm
    WeightApprox. 7.6 kgAbout7.6kgAbout7.6kgAbout7.6kg
    Power supply24 V DC, supplied by 3A power adapterAC 24V, 3A Power adapter power supplyAC 24V, 3A Power adapter power supplyAC 24V, 3A Power adapter power supply
    Illuminant Life Span> 3 million measurements in 5 years5 years, more than 3 million times measurements5 years, more than 3 million times measurements5 years, more than 3 million times measurements
    DisplayTFT True Color 7 inch, Capacitive Touchscreen7-inch TFT color LCD, Capacitive Touch Screen7-inch TFT color LCD, Capacitive Touch Screen7-inch TFT color LCD, Capacitive Touch Screen
    InterfaceUSB, Print Serial,BluetoothUSB, Print serial portUSB, Print serial portUSB, Print serial port
    Data Storage5,000 samples, 20,000 samplesStandard 1000 pcs,sample 20000 pcsStandard 1000 pcs,sample 20000 pcsStandard 1000 pcs,sample 10000 pcs
    LanguageSimplified Chinese, Traditional Chinese, EnglishSimplified Chinese,Traditional Chinese,EnglishSimplified Chinese,Traditional Chinese,EnglishSimplified Chinese,Traditional Chinese,English
    Operating Temperature0 to 40 ° C (32 to 104 ° F)0~40℃(32~104°F)0~40℃(32~104°F)0~40℃(32~104°F)
    Storage Temperature- 20 – 50 ° C (-4 – 122 ° F)-20~50℃(-4~122°F)-20~50℃(-4~122°F)-20~50℃(-4~122°F)
    Standard AccessoriesPower adapter, user manual, quality management software (download), USB cable, 0% calibration box, measuring aperturePower Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture.Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture.Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture.
    Optional AccessoriesMicro printer, Test Fixture, Standard Haze Sheet, FootswitchMicro-printer,Test fixture, standard haze sheet, foot switchMicro-printer,Test fixture, standard haze sheet, foot switchMicro-printer,Test fixture, standard haze sheet, foot switch
    Notes:Subject to change without noticeThe specifications are subject to change without notice.The specifications are subject to change without notice.The specifications are subject to change without notice.
    Quality 3nh YH1000 Haze Meausring Instrument ASTM D1003 Non Compensation Method for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen ThreeNH Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)