Sign In | Join Free | My himfr.com
Home > Color Difference Meter >

Digital Color Difference Meter Test Instrument 3nh NH300 With 8mm Measurement Aperture

    Buy cheap Digital Color Difference Meter Test Instrument 3nh NH300 With 8mm Measurement Aperture from wholesalers
     
    Buy cheap Digital Color Difference Meter Test Instrument 3nh NH300 With 8mm Measurement Aperture from wholesalers
    • Buy cheap Digital Color Difference Meter Test Instrument 3nh NH300 With 8mm Measurement Aperture from wholesalers
    • Buy cheap Digital Color Difference Meter Test Instrument 3nh NH300 With 8mm Measurement Aperture from wholesalers

    Digital Color Difference Meter Test Instrument 3nh NH300 With 8mm Measurement Aperture

    Ask Lasest Price
    Brand Name : 3nh
    Model Number : NH300
    Certification : CE,RoHs,ISO,etc.
    Price : discuss
    Payment Terms : T/T,Paypal, etc
    Supply Ability : 1000pcs/month
    Delivery Time : 2 work days
    • Product Details
    • Company Profile

    Digital Color Difference Meter Test Instrument 3nh NH300 With 8mm Measurement Aperture

    Cheap 3nh NH300 Colorimeter Chroma Meter Color Test Instrument with 8mm Measurement Aperture


    Company Information

    Shenzhen 3nh Technology Co., Ltd. is a high-tech enterprise. We research, develop, produce and market photoelectric detection products in photoelectric detection technology field and color management field.


    After years of intensive research.3nh has launched NS series spectrophotometer and NH, NR series colorimeter, ISO12233 resolution test chart, optical image test solution and specific standard illuminant which are widely used in plastic, electronic, paint, ink, textile, garment, printing and dyeing, food, medical, cosmetic, optical image test industries and the field of scientific research, school and laboratory.


    We can provide customization service which has been well received by customers. 3nh cherishes talents, focuses on talents.

    Digital Color Difference Meter Test Instrument 3nh NH300 With 8mm Measurement Aperture

    Specification

    NH300
    Illuminating/Viewing Geometry8/d
    Measuring ApertureΦ8mm
    DetectorSilicon photoelectric diode
    Color SpaceCIEL*a*b*C*h* CIEL*a*b*
    Color Difference FormulaE*ab L*a*b E*C*h
    Light SourceD65
    Light Source DeviceLED blue light excitation
    Errors Between Each Equipment≤0.40E*ab
    Storage100pcs standards 20000pcs samples
    Repeatability

    Standard deviation within ΔE*ab 0.07

    Average of 30 measurements of standard white plate

    Weight500g
    Dimension205×70×100 mm
    Power sourceRechargeable lithium-ion battery 3.7V@3200mAh
    Lamp Life5 years, more than 1.6 million measurements
    Charging Time2 hours (first time 8 hours--100% electricity)
    Measurement Times Before RechargingMore than 3000 times
    Operating Temperature/Humidity Range-10~40℃, relative humidity 0~85% with no condensation
    Data InterfaceUSB
    Extended Aperture (optional)-
    Printer (optional)Miniature thermal printer

    Image

    Cheap 3nh NH300 Colorimeter Chroma Meter Color Test Instrument with 8mm Measurement Aperture

    Cheap 3nh NH300 Colorimeter Chroma Meter Color Test Instrument with 8mm Measurement Aperture

    Cheap 3nh NH300 Colorimeter Chroma Meter Color Test Instrument with 8mm Measurement Aperture

    Cheap 3nh NH300 Colorimeter Chroma Meter Color Test Instrument with 8mm Measurement Aperture


    FAQ

    1. When I received NH310/NH300 colorimeter and perform measurement, why the measured data is abnormal?


    After receiving NH310/NH300, you have to perform white and black calibration manually when first starting.


    2. In which condition, manual white and black calibration and auto calibration are required for NH310?


    a. It’s needed to perform manual calibration for NH310 when first starting.
    b. In the subsequent starting, NH310 will perform auto calibration at startup. No need to perform manual calibration.
    c. Suggestion: it’s best to perform manual calibration once a week or when NH310 measured data is not accurate.


    3. In which condition, manual white and black calibration for NH300 is required?


    a. It’s needed to perform manual calibration for NH300 when first starting.


    b. In the subsequent starting, no need to perform manual calibration.


    c. Suggestion: it’s best to perform manual calibration once a week or when NH300 measured data is not accurate.

    4. How to replace NH310 measuring aperture?


    There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)
    a. Turning on
    b. Removing measuring aperture, install the needed measuring aperture.


    c. Select “Settings-Aperture Setting” in main menu to select corresponding measuring aperture.


    d. After selecting aperture, the instrument will display “White and Black Calibration” interface. White and black calibration must be performed.
    e. Replace completed.


    5. CQCS3 (Color Quality Control System) Installation


    a. Before installation, please Copy CQCS3 folder to your computer and don’t remove any files in CQCS3 folder.


    b. Double-click the setup.exe to install CQCS3 software.


    c. Then double-click Install.bat under the CQCS3USB_Driver file to install the driver.
    d. Detailed installation information please read the "Installing Software" under CQCS3 User manual.doc.

    Packaging & Shipping

    Size45*23*38mm
    Gross weight4kg
    Standard accessoryPower Adapter, USB Cable, User Manual, CD (Including QC Software), Calibration Plate
    Optional accessorymicro printer,powder test box, universal test components,
    Our Services

    We can ship by DHL, Fedex, UPS, TNT, SF express etc door to door, and we support 1 year warranty except consumables.


    Related Knowledge about Spectrophotometer:


    Color Space

    CIE LAB
    -L(Lightness)-0 is black,100 is white
    -a(Red-Green)-positive values are red; negative values are green and 0 is neutral
    -b(Blue-Yellow)-positive values are yellow;negative values are blue abd 0 is neutral

    CIE LCH
    L: Lightness,value is the same in each scale C:Chroma H:Hue Angle

    dE Total Color difference
    Delta-E is a measurement used to indicate how much a color deviates from an accepted standards.The higher the dE, the more inaccurate the color.

    Waiting for you inquiry. Any more questions you can contact me directly, I will reply asap.


    Quality Digital Color Difference Meter Test Instrument 3nh NH300 With 8mm Measurement Aperture for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen ThreeNH Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)